Porterrshow örnek çıktı:

FID1:admin> porterrshow
          frames      enc    crc    crc    too    too    bad    enc   disc   link   loss   loss   frjt   fbsy    c3timeout    pcs
       tx     rx      in    err    g_eof  shrt   long   eof     out   c3    fail    sync   sig                   tx    rx     err
  0:  838.0m   2.4g   0      1      1      0      0      0      0      0      0      0      0      0      0      0      0      0   
  1:    7.9m   1.8g   0      0      0      0      0      0      0      0      0      0      0      0      0      0      0      0   
  2:    7.4m   1.1g   0      0      0      0      0      0      0      0      0      0      0      0      0      0      0      0

Frames tx/rx

– İletilen frame sayısını temsil eden sayaçlar bu kolonda bulunur. Burası port üzerindeki trafiği ölçmek için bir sayaçtır.
enc_in – frame içindeki 8 bit / 10 bit kodlama hataları. Bu kodlama bozuksa veya bir hata algılanırsa ve bu sayaç artıyorsa, SFP / kablonun kontrol edilmesi / değiştirilmesi gerekir.

enc in/out

Bu sayaç değeri yüksek ise bu bir donanım probleminin işaretidir. Önerilen eylemler, kabloyu veya SFP’yi değiştirmek, kabloyu başka bir porta taşımak veya porttest çalıştırmak olacaktır.

enc_out hataları kablo / SFP sorunu anlamına gelir. Enc_out ve crc_err hataları GBIC / SFP sorunu anlamına gelir.

crc_err

Bu sayaç değeri yüksek ise bu bir GBIC / SFP probleminin işaretidir. Önerilen eylemler, kabloyu veya SFP’yi değiştirmek, kabloyu başka bir porta taşımak veya porttest çalıştırmak olacaktır.

Too_long

FC frames are 2148 bytes maximum. Frames that were longer than the FC maximum (SOF+header+2112bytes+CRC+EOF). If an eof is corrupted or data generation is incorrect a too_long error is reported.

Too_short

The too_short error statstics counter is incremented whenever a frame, bounded by an SOF and EOF, is received and the number of words between the SOF and EOF is less than 7 words (6 words header plus 1 word CRC), i.e. 38 bytes (not 48) including the SOF and EOF.
This could be caused by the transmitter, or an unreliable link.

bad_eof

– After a loss of synchronization error continuous mode alignment allows the receiver to reestablish word alignment at any point in the incoming bit stream while the receiver is operational. Such realignment is likely (but not guaranteed) to result in code violations and subsequent loss of synchronization. Under certain conditions, it may be possible to realign an incoming bit stream without loss of synchronization. If such a realignment occurs within a received frame, detection of the resulting error condition is dependent upon higher-level function (e.g., invalid CRC,missing EOF Delimiter).

Disc c3

– Discard class 3 errors could be generated by a switch when devices send frames without performing a FLOGI first or send frames to an invalid destination. This error is just reporting that such a discard occurred.

Link fail

– If a port remains in the LR Receive State for a period of time greater than a timeout period (R_T_TOV), a Link Reset Protocol Timeout shall be detected which results in a Link Failure condition (enter the NOS Transmit State). The link failure also indicates that loss of signal or loss of sync lasting longer than the R_T_TOV value was detected while not in the Offline state.

Loss sync

– Synchronization failures on either bit or transmission word boundaries are not separately identifiable and cause loss-of synchronization errors.

Loss sig

– Loss of signal

Bir Cevap Yazın

Aşağıya bilgilerinizi girin veya oturum açmak için bir simgeye tıklayın:

WordPress.com Logosu

WordPress.com hesabınızı kullanarak yorum yapıyorsunuz. Çıkış  Yap /  Değiştir )

Twitter resmi

Twitter hesabınızı kullanarak yorum yapıyorsunuz. Çıkış  Yap /  Değiştir )

Facebook fotoğrafı

Facebook hesabınızı kullanarak yorum yapıyorsunuz. Çıkış  Yap /  Değiştir )

Connecting to %s